44 mm high aluminium rail for PV panels mounting systems.
Rail SolarFish
SolarFish is a 44 mm high aluminium rail for PV mounting systems on pitched and flat roofs. The two side grooves and the lower groove are compatible with SKS M8 screws or RHS hammer head screws and make the installation quick and easy. SolarFish is compatible with both PM U / PMC U universal clamps and PM F / PM C pre-assembled clamps. The different lengths available are optimized to suit with different panels sizes. SolarFish is compatible with PV systems on pitched roofs with tiles (in combination with aluminium and stainless steel hooks), non-removable corrugated panel or barrel /flat tiles (in combination with STSR and STSI double-threaded screws), trapezoidal metal sheets (in combination with DLA and DLAK clamps) and flat roofs (in combination with STFS and STFN triangular frames).
Different rails lengths optimized for different panels sizes.
Compatible with installation both from the side and from the bottom.
Compatible with SKS M8 hexagonal screws or RHS hammer head screws.
Suitable for the quick couplings of the aluminium hooks.
Properties
Aluminium alloy AW 6063 T6 in accordance with EN 755-2:2013.
Dovoljenje aplikaciji
Applications
Aluminium rail for PV panels mounting systems suitable for the whole clamps range, in combination with tiles hooks, double-threaded screws, triangles and standing seam clamps.
Navodila uporabe
Functionality
Identify the correct support components based on the type of roof (e.g. tile hooks, double threaded-screws, triangular frames, standing seam clamps, etc).
Position the rail on the support components (use SOLARPANEL-FIX software to design the system).
Use 1 CPN AL joint on both sides to connect the rails (a complete connection requires 2 CPN AL joints).
Slide the CPN AL joint until the central stud touches the end side of the rail.
Every CPN AL joint has to be connected to the rails with four 3.5 mm x 9.5 mm self-drilling screws (two screws per rail side).
Consider a thermal break of at least 50 mm every 15 m.
Position the PV panels and fasten the clamps.
Apply the AK SP caps to the ends of the SolarFish rail.